Table of Contents
The colour rendering index, written CRI or Ra, scores out of 100 how faithfully a light shows colours compared with a reference light of the same colour temperature. The figure on the box is only the average of eight soft test colours: saturated red and the greens are left out. Choose CRI 90 wherever you judge a colour.
Two LED bulbs on the same shelf: same wattage, same warm white, same price, both marked CRI 80. Fit the first and the burgundy sofa goes brown, the tomatoes on the chopping board look cooked and your face in the bathroom mirror looks like the end of a long week. The second would have left the room looking alive. One number separates them, and it is not the one printed on the front of the box. This guide explains what CRI lighting figures really measure, what they leave out, what 80, 90 and 95 look like at home, and where to find the value that settles the question.
What the colour rendering index measures
The principle fits in one sentence. Standard colour samples are lit by the lamp under test, then by a reference light, and the shift in each colour between the two is measured. No shift, and the index is 100; the bigger the shift, the lower it falls. The method was set out by the International Commission on Illumination (CIE) and is published today as CIE 13.3-1995. The EU ecodesign regulation for light sources defines it the same way: the CRI is the average of the colour rendering of the first eight test colours, R1 to R8.
Two details of that method explain almost everything else in this guide.
The reference is not always the same light. Below 5,000 K it is a black body at the same temperature as the lamp, in other words the glow of a flame or a filament. Above 5,000 K it is a phase of daylight. Either way, the reference always has the colour temperature of the lamp being tested. That clears up the most common confusion about what CRI is: it says nothing about the tint of the light. A very yellow 2,700 K source can score 95, and a crisp white one only 80. Choosing between warm white vs cool white is a separate decision, made in kelvins.
The figure on the box is an average. Each sample gets its own score, worked out as 100 minus 4.6 times its colour shift: R1, R2, R3 and so on, and a very poor result can fall below zero. The general index printed on the pack, Ra, is the plain average of the first eight samples, and only those eight. The index is also only defined for light that is close to white: a coloured party bulb has no meaningful CRI.
Two more points help when you compare. A gap of about 5 points is roughly the smallest difference the eye notices between two lights, so a CRI of 82 and a CRI of 85 are, for you, the same lamp. And CRI has nothing to do with brightness: the amount of light is given in lumens, the tint in kelvins, the faithfulness of the colours by the colour rendering index. Three figures, three questions.
Why two bulbs rated CRI 80 can look nothing alike: R9 and the colours left out
The CIE method defines fourteen test colours. The eight used for the general index are soft, mid-saturation tints spread around the colour wheel, from greyish pink to pale violet. The other six are the difficult colours, the ones that catch a lamp out, and none of them counts.
| Test colour | What it stands for | Counted in the CRI on the box? |
|---|---|---|
| R1 to R8 | Eight mid-saturation tints around the whole colour wheel | Yes, the CRI is their average |
| R9 | Saturated red | No |
| R10 | Saturated yellow | No |
| R11 | Saturated green | No |
| R12 | Saturated blue | No |
| R13 | Light skin tone | No |
| R14 | Leaf green, a mid olive | No |
Read the list of exclusions again: the deep red of an armchair, the green of a houseplant or an olive wall, and your own face in the mirror. A lamp can render all three badly and still show 80 quite legally, because its eight soft tints come out fine. That is not a trick by the maker. It is how the index is defined.
The missing figure does exist, and it is public. Under the EU energy labelling rules for light sources, every supplier enters a product information sheet into the European product database, EPREL, and for LED and OLED sources that sheet must give the R9 value separately. Almost nobody looks at it. We did: fifty sheets picked at random by registration number on 16 October 2026, each checked again in the public database the next day. Forty-eight were still published and readable.
| CRI declared | Sheets | Lowest R9 | Highest R9 | Median R9 |
|---|---|---|---|---|
| 80 | 27 | minus 9 | 80 | 4 |
| 81 to 89 | 11 | minus 3 | 23 | 10 |
| 90 and above | 8 | 7 | 80 | 50 |
Twenty-seven sheets declare exactly 80. Their median R9 is 4, close to nothing: half of these lamps render almost no saturated red, and eight sit at zero or below, down to minus 9. Yet one of them, with the same 80 on the label, declares an R9 of 80. On a red fabric the gap between those two lamps is striking, and nothing on the box gives it away. Two sheets in the sample even declared less than 80, one at 70 with an R9 of minus 23: the legal floor has exceptions, covered in the next section.
Higher up the scale the spread narrows without vanishing. From CRI 90 the median R9 rises to 50, but one sheet still shows 7. A high CRI makes a good R9 likely, never certain. If red matters in your home, a burgundy wall, a cherry table, a red sofa, look the value up rather than assume it.
Greens are worse off, since neither saturated green nor leaf green is counted and no sheet has to publish them. That is why the same painted wall can change character from one bulb to the next, a problem our guide to what colour goes with green works through shade by shade. In a green room, the general index is not enough on its own. If that green was chosen for its calm, our guide to calming colours explains why a warm evening light greys it, and which shades hold up better.
Is a CRI of 80 good? What 80, 90 and 95 look like
The floor of 80 is not a marketing habit, it is the law. Commission Regulation (EU) 2019/2020, which applies directly in Ireland as in every Member State, has required a colour rendering index of at least 80 for light sources since 1 September 2021 (Annex II, Table 4). There are two exceptions: high-intensity discharge lamps above 4,000 lumens, and light sources meant for outdoor, industrial or other uses where lighting standards allow less, on condition that the packaging and the documentation say so clearly. A bulb sold here for use in the home is therefore at 80 or above, unless its box tells you otherwise.
That floor has become the default of the market, so the real question is never 70 or 80, but 80 or 90. With the 5-point rule in mind, our reading of the scale is simple.
| CRI on the box | What you actually see | Where it is enough |
|---|---|---|
| 80 to 84 | Pastels and neutrals look fine. Reds fade, warm wood drifts towards grey, greens all look alike. | Hall, landing, utility room, attic |
| 85 to 89 | A visible step up on a fabric or a coloured wall, mostly when you compare two rooms side by side. | Bedroom, living room with pale walls |
| 90 to 94 | Saturated colours come back. The first level where a red stays red and a skin tone looks believable. | Kitchen, wardrobe, bathroom mirror, a strongly coloured room |
| 95 and above | Hard to tell from 90, except on two very close shades laid side by side. | Sewing, painting, a hobby desk |
Our view: going from 80 to 90 changes the room, going from 90 to 95 changes a task. Paying extra for 95 in a sitting room makes little sense; paying it for the light over a craft table does.
What CRI you need, room by room
The useful question is not “which CRI for this room” but “do I judge a colour here”. On a landing you judge a step and a distance. At a mirror or a chopping board you judge a shade, and you act on what you see.
| Room or task | What you judge by eye | CRI we recommend |
|---|---|---|
| Wardrobe, dressing area | The colour of a garment, whether two pieces match | 90, or 95 with many close shades |
| Kitchen worktop | Whether meat is cooked, whether vegetables are fresh | 90 |
| Bathroom mirror | Skin tone, make-up, hair colour | 90 |
| Sewing, painting, crafts | One shade against another | 95 |
| Strongly coloured wall, sofa or rug | The depth of the colour you chose | 90 |
| Hall, stairs, landing | Nothing, you are passing through | 80 is enough |
| Garage, utility room, hot press | Nothing either | 80 is enough |
Three cases deserve a closer look. In a wardrobe, the classic mistake is to add brightness instead of quality: a rail flooded by a CRI 80 source still will not tell you whether a jumper is olive or khaki, and our guide to wardrobe lighting covers placement and lumens in full. In front of a painting it works the other way round: the amount of light has to stay modest to protect the pigments, so quality is all you have left, and our guide to picture lights gives the angles and distances. At the bathroom mirror, a CRI of 90 is what keeps foundation and hair colour honest, so that what looked right indoors still looks right in daylight.
Over a worktop, the fitting matters as much as the source. A continuous line hung along the worktop, like our LED pendant lights, lights the chopping board without your shoulders casting a shadow on it. The 118 cm LED batten pendant in the products below gives 3,640 lumens at CRI 90, in warm white 3000 K or neutral white 4000 K. Over a dining table in a room painted a deep colour, the square LED frame chandelier, 80 by 80 cm, also declares CRI 90 in warm white. Our guide to kitchen island lighting covers the hanging height and the number of pendants.
Where to find the CRI: the box, the 830 code and the EPREL sheet
On a bulb sold in its own box, the CRI is not optional: the EU ecodesign regulation requires it on the packaging, rounded to a whole number. It is often printed on the back or the side rather than the front. You will meet it in one of three forms, the last of them only on fittings.
Stated in full. “CRI 90”, “Ra 90” or “Ra > 90” all mean the same thing. CRI is the everyday name, Ra the technical name of the general index.
As a three-digit code. A marking such as 830, 930 or 940 packs two figures into one. The first digit gives the tens of the CRI, the next two the colour temperature in hundreds of kelvins. So 830 reads as CRI 80 to 89 at 3,000 K, and 940 as CRI 90 to 99 at 4,000 K. It is a lamp makers’ code, long familiar on fluorescent tubes, and not every brand prints it.
Not at all, on a fitting. That is the usual case with built-in LEDs: the packaging rule covers a light source sold on its own, not the fitting that contains one. The official sheet is then the place to look.
That sheet is the most underused resource in the lighting aisle. Every light source sold in the European Union is registered in EPREL, and the energy label carries a QR code that leads straight to its entry. The product information sheet you can download there gives the colour rendering index rounded to a whole number and, in a section reserved for LED and OLED sources, the R9 value. It also gives the useful luminous flux and the on-mode power, which you will need in the next section.
In practice: scan the QR code on the label in the shop, or type the registration number from the box into the database. You get the R9 value, which the box does not give you, and it is the only reliable way to separate two “CRI 80” bulbs a couple of euro apart. Our guide to LED bulbs covers the other figures on the pack, and remember that many Irish ceiling roses still take a B22 bayonet bulb, so check the cap before you fall for a high-CRI model. Whatever its CRI, a bulb must also stay within the limit printed on the fitting: our guide explains whether you can use a 60 W bulb in a 40 W lamp. For a fitting with integrated LEDs, where the source cannot be swapped later, ask the question before you buy: our LED lights show the CRI on their product page whenever the maker documents it.
Does a high CRI cost more energy?
A little, and for a physical reason. A standard white LED is a blue chip coated with a phosphor that turns part of the blue into yellow. The mix looks white but is short of deep red, which is exactly what drags R9 down. To fill the gap, the maker adds a phosphor that emits in the deep red, around 650 nanometres and beyond. The eye is far less sensitive there: at 650 nm it needs roughly ten times the power it needs at 555 nm, in the green, to see the same brightness. The spectrum improves, the efficiency drops.
The EU regulation puts a figure on that trade-off, the only public and checkable one we found. In Regulation (EU) 2019/2020, the maximum power a light source may draw for a given light output is multiplied by a CRI factor equal to the CRI plus 80, divided by 160. A CRI 80 source gets a factor of 1.00, a CRI 90 source 1.06, a CRI 95 source 1.09. In plain terms, the rules allow a CRI 90 lamp to use about 6% more power than a CRI 80 lamp for the same light. On a 7 W bulb that is under half a watt: lit three hours a day, about half a kilowatt hour a year.
We found no independent public measurement of the real loss in lumens per watt between two products of the same generation, one at 80 and one at 90. The figures that circulate come from sales literature, and we do not repeat them. The sound method is to compare, on two EPREL sheets, the useful luminous flux divided by the on-mode power. And before comparing anything, work out the light the room needs: our guide how many lumens do I need gives the figures room by room.
Our method in three questions
Three questions are enough.
Do I judge a colour here? If not, the default CRI 80 is fine, and your budget is better spent on lumens or on where the lights go.
Which colour, exactly? For a red, a warm wood or a skin tone, ask for the R9 as well as the CRI. For a green, take 90 at least, since the general index measures no saturated green.
Is the figure written anywhere? Our advice: when the value appears neither on the box, nor on the product page, nor in EPREL, assume 80 and decide from there.
If you remember one thing, make it this: the colour rendering index is chosen room by room, not once for the whole house. CRI 90 over the worktop and in the wardrobe, CRI 80 on the landing and in the garage.
Colour rendering index: frequently asked questions
Is a CRI of 80 good?
It is the legal minimum for most light sources sold in the European Union since 1 September 2021, and it is fine where you do not judge colours: a hall, a landing, a garage. It is not enough where you do. At 80, pastels and neutrals look right but reds fade, warm wood turns greyish and greens look alike, and in our sample of EPREL sheets the median R9 of CRI 80 sources was only 4. For a kitchen worktop, a wardrobe or a mirror, choose 90.
Can you tell the difference between 80 and 90 CRI?
Yes. A gap of about 5 points is roughly the smallest difference the eye notices between two lights, so 10 points show clearly, above all on saturated colours. Under CRI 90 a red stays red, an oak floor keeps its warmth and a skin tone looks believable; under CRI 80 the same things look flatter. The other side of the trade-off is small: the EU rules allow a CRI 90 lamp about 6% more power than a CRI 80 lamp for the same light output.
Which lamps have a CRI of 100?
The reference sources themselves. Incandescent and halogen bulbs score close to 100 because they are, in effect, the black body the index compares against, and daylight is the reference above 5,000 K. LEDs come close without reaching it: standard white LEDs sit at 80 or a little more, high-CRI models around 95, and the best models are quoted at 98 or 99. For an LED, the R9 value on its EPREL sheet tells you more than a few extra points of CRI.
Is CRI the same as lumens?
No. Lumens measure how much light a bulb gives, the colour rendering index measures how faithfully that light shows colours, and the colour temperature in kelvins describes its tint, from warm to cool. The three are independent: a bright 1,500 lumen bulb can have a CRI of 80, and a dim 400 lumen one a CRI of 95. Check all three on the box or on the EPREL product information sheet.
What does 830 or 940 mean on an LED bulb?
It is a three-digit code used by lamp makers. The first digit gives the tens of the colour rendering index, the next two the colour temperature in hundreds of kelvins. A bulb marked 830 has a CRI between 80 and 89 in warm white 3,000 K; one marked 940 has a CRI between 90 and 99 in neutral white 4,000 K. Not every brand prints the code, so when it is missing, look for the CRI in full or on the EPREL sheet.
Which is whiter, 3000K or 5000K, and does it change the CRI?
5,000 K is whiter and cooler; 3,000 K is a warm white with more yellow in it. The colour temperature does not change the colour rendering index, because the index always compares a lamp with a reference light of the same colour temperature. A 3,000 K bulb can score 95 and a 5,000 K bulb only 80. Choose the kelvins for the mood of the room and the CRI for the faithfulness of the colours.
Sources
- CIE 13.3-1995, Method of measuring and specifying colour rendering properties of light sources: fourteen test colour samples, the first eight for the general index Ra, special index of 100 minus 4.6 times the colour shift, black body reference below 5,000 K and daylight above. International Commission on Illumination
- Commission Regulation (EU) 2019/2020, ecodesign requirements for light sources: definition of the CRI as the average of R1 to R8 (Article 2), CRI factor (CRI + 80) / 160 in the maximum allowed power (Annex II, point 1), CRI of at least 80 from 1 September 2021 and its exceptions (Annex II, Table 4), CRI rounded to a whole number on the packaging of a light source sold on its own (Annex II, point 3(b)). Official Journal of the European Union
- Commission Delegated Regulation (EU) 2019/2015, energy labelling of light sources: QR code on the label, product information sheet giving the CRI and, for LED and OLED sources, the R9 value (Annex V, Table 3); fifty EPREL sheets drawn on 16 October 2026, forty-eight checked again on 17 October. European Commission
- Colour rendering index (English edition: reference illuminants, test colour samples, typical values), Indice de rendu des couleurs (French edition: a gap of about 5 close to the smallest perceptible difference) and Lichtfarbe (German edition: three-digit lamp colour code). Wikipedia
- Photopic luminous efficiency function V(λ): relative sensitivity of the eye of about 0.11 at 650 nm against 1 at 555 nm. International Commission on Illumination
Related products